Hyundai Equus Manuals

Hyundai Azera: Immobilizer Control Unit Repair procedures - Immobilizer System - Body Electrical System - Hyundai Azera 2011-2026 Service ManualHyundai Azera: Immobilizer Control Unit Repair procedures

Removal
1.
Disconnect the negative (-) battery terminal.
2.
Remove the crash pad lower panel.
3.
Disconnect the connector of the immobilizer unit and then remove the immobilizer unit (A) after loosening the nut.

   
Using a suitable tool, cut slots into the heads of the shear bolts.
Wear safety glasses to protect your eyes from flying bits of metal.
Wear work gloves to protect your hands from any sharp metal edges on the shear bolt.
Installation
1.
Install the immobilizer control unit after connecting the unit connector.
2.
Install the crash pad lower panel.
   
Do not reuse the shear bolts.
Tighten the new shear bolts until the hex heads twist off.
Repair procedures
Teaching Procedures 1. Key Teaching Procedure Key teaching must be done after replacing a defective PCM(ECM) or when providing additional keys to the vehicle owner. The procedure starts with a ...

Antenna Coil Repair procedures
Removal 1. Disconnect the negative (-) battery terminal. 2. Remove the crash pad lower panel. (Refer to Body - "Crash Pad Lower Panel") 3. Disconnect the 6P connector (B) of the coil ante ...

See also:

Drive Belt Components and Components Location
Components 1. Drive belt ...

CVVT Oil Control Valve (OCV) Repair procedures
Inspection 1. Turn the ignition switch OFF. 2. Disconnect the OCV connector. 3. Measure resistance between the OCV terminals 1 and 2. 4. Check that the resistance is within the specifi ...

Fuel Pump Motor Repair procedures
Removal 1. Remove the fuel pump. (Refer to Fuel Delivery System - “Fuel Pump”) 2. Disconnect the electric pump wiring connector (A) and the fuel sender connector (B). 3. Remove the c ...

Categories

Hyundai Azera Manuals

2011-2026 Copyright www.hgmanual.com