Inspection
1.
Connect the battery voltage and check the blower motor rotation.

2.
If the blower motor voltage is not operated well, substitute with a known-good blower motor and check for proper operation.
3.
If the problem is corrected, replace the blower motor.
Replacement
1.
Disconnect the negative (-) battery terminal.
2.
Remove the crash pad lower cover (A) and then disconnect the connector (B).

3.
Disconnect the of the blower motor connector(A) and then remove the blower motor (B).

4.
Installation is the reverse order of removal.
Blower Unit Repair procedures
Replacement 1. Disconnect the negative (-) battery terminal. 2. Remove the heater and blower unit. (Refer to Heater - "Heater Unit") 3. Remove the blower unit (A) from the heater unit ...

Power Mosfet Repair procedures
Inspection 1. Ignition "ON" 2. Manually operate the control switch and measure the voltage of blower motor. 3. Select the control switch to raise voltage until high speed. 1. Drain2. Dr ...

See also:

Glove Box Housing Repair procedures
Replacement     • When prying with a flat-tip screwdriver, wrap it with protective tape, and apply protective tape around the related parts, to prevent damage. • Take ...

Automatic turn off function  (if equipped)
The interior lights automatically turn off approximately 20 minutes after the ignition switch is turned off. With the theft alarm system, the interior lights automatically turns off approximately 5 ...

Front Seat Back Cover Repair procedures
Replacement     • Use a plastic panel removal tool to remove interior trim pieces to protect from marring the surface. • Take care not to bend or scratch the trim and pan ...

Categories

Hyundai Azera Manuals


© 2011-2024 Copyright www.hgmanual.com