Hyundai Equus Manuals

Hyundai Azera: Blower Unit Repair procedures - Blower - Heating,Ventilation, Air Conditioning - Hyundai Azera 2011-2026 Service ManualHyundai Azera: Blower Unit Repair procedures

Replacement
1.
Disconnect the negative (-) battery terminal.
2.
Remove the heater and blower unit.
(Refer to Heater - "Heater Unit")
3.
Remove the blower unit (A) from the heater unit after loosening a mounting bolt and 3 screws.

   
Make sure that there is no air leaking out of the blower and duct joints.
4.
Installation is the reverse order of removal.
Blower Unit Components and Components Location
Component Location Components 1. Duct Seal2. Duct Case3. Inlet Door4. Intake Actuator5. Inlet Duct Case (A)6. Climate control air filter7. Cluster Ionizer8. Climate control air filter Cover9. Bl ...

Blower Motor Repair procedures
Inspection 1. Connect the battery voltage and check the blower motor rotation. 2. If the blower motor voltage is not operated well, substitute with a known-good blower motor and check for prop ...

See also:

Rail Pressure Sensor (RPS) Schematic Diagrams
Circuit Diagram ...

Fuel Pump Repair procedures
Inspection [Fuel pump] 1. Turn the ignition switch OFF, and then remove battery (-) cable. 2. Remove the fuel pump assembly. 3. Check motor operation by fuel pump connector (A) connecti ...