Hyundai Equus Manuals

Hyundai Azera: Fuel Tank Air Filter Repair procedures - Evaporative Emission Control System - Emission Control System - Hyundai Azera 2011-2026 Service ManualHyundai Azera: Fuel Tank Air Filter Repair procedures

Removal
1.
Turn the ignition switch OFF and disconnect the battery negative (-) cable.
2.
Lift the vehicle.
3.
Disconnect the canister close valve connector (A).
4.
Disconnect the ventilation hose (B) from the fuel tank air filter and canister close valve.
5.
Remove the fuel tank air filter assembly after removing bolts (C).

6.
Release the lever (A), and then separate the canister close valve (B) from the fuel tank air filter (C) after rotating it in the direction of the arrow in the figure.

Installation
•
Install the component with the specified torques.
•
Note that internal damage may occur when the component is dropped. In this case, use it after inspecting.
1.
Installation is reverse of removal.
Fuel Filler Cap Description and Operation
Description A ratchet tightening device on the threaded fuel filler cap reduces the chances of incorrect installation, which would seal the fuel filler. After the gasket on the fuel filler cap ...

Exhaust Emission Control System
...

See also:

Description and Operation
Description Mobile Telematics System (MTS) Hyundai motor companies are now faced with the task of shifting their paradigm from vehicle-centered services to customer valuecentered services, wit ...

Positive Crankcase Ventilation (PCV) Valve Description and Operation
Operation Principle ...

Main Crash Pad Assembly Components and Components Location
Component Location 1. Main crash pad assembly ...

Categories

Hyundai Azera Manuals

© 2011-2026 Copyright www.hgmanual.com