Inspection |
1. |
Turn ignition switch OFF. |
2. |
Disconnect the solenoid valve connector. |
3. |
Measure resistance between sensor signal terminal and sensor ground terminal. |
4. |
Check that the resistance is within the specification.
|
Removal |
1. |
Remove the battery and the battery tray.
|
2. |
Remove the under cover (A).
|
3. |
Replace new gasket and the plug after draining the automatic transaxle fluid by removing the drain plug.
(Refer to Hydraulic System - "Fluid") |
4. |
Remove the valve body cover (B) and eyebolt (A).
|
5. |
Remove the bolt (3ea) after disconnecting the solenoid valve connector (A) and the oil temperature sensor connector (B).
|
6. |
Remove the solenoid valve (B) after removing the solenoid support (A). |
Installation |
1. |
Installation is the reverse of removal. |
|
Cluster ionizer Description and Operation
Description
1.
The function of cluster ion generator is cleaning air by sterilizing and dissolving of air conditioner.
2.
The function of cluster ion generator is controlling mold caused by st ...
Inhibitor Switch Troubleshooting
Fault Diagnosis
Fault Diagnosis for Symptom
Major Symptom Expected Cause Items to Check and Measures Shift lever not operating Gear not marked on cluster Shock occurs wh ...
General Information
General Troubleshooting Information
Before Troubleshooting
1.
Check applicable fuses in the appropriate fuse/relay box.
2.
Check the battery for damage, state of charge, and clean and tight c ...