Hyundai Equus Manuals

Hyundai Azera: Fuel Pressure Control Valve (FPCV) Repair procedures - Engine Control System - Engine Control/Fuel System - Hyundai Azera 2011-2026 Service ManualHyundai Azera: Fuel Pressure Control Valve (FPCV) Repair procedures

Inspection
1.
Turn the ignition switch OFF and disconnect the battery negative (-) cable.
2.
Disconnect the fuel pressure regulator valve connector.
3.
Measure resistance between the fuel pressure regulator valve terminals 1 and 2.
4.
Check that the resistance is within the specification.

Specification: Refer to “Specification”

Removal
(Refer to Fuel Delivery System - "High Pressure Fuel Pump")
Installation
(Refer to Fuel Delivery System - "High Pressure Fuel Pump")
Fuel Pressure Control Valve (FPCV) Schematic Diagrams
Circuit Diagram ...

Canister Close Valve (CCV) Description and Operation
Description Canister Close Valve (CCV) is installed on the canister ventilation line. It seals evaporative emission control system by shutting the canister from the atmosphere when leakage dete ...

See also:

Radiator Hose Repair procedures
Removal and Installation 1. Remove the battery and tray. (Refer to Engine Electrical System - "Battery") 2. Remove the air duct and air cleaner assembly. (Refer to Intake And Exhaust Syste ...

GVW (Gross vehicle weight)
This is the Base Curb Weight plus actual Cargo Weight plus passengers. ...

Emergency starting
Connect cables in numerical order and disconnect in reverse order. Positive (+) battery terminal on your vehicle Positive (+) battery terminal on the booster battery Negative (-) battery ter ...