Underdrive brake control solenoid valve(UD/B) is attached to
the valve body. This variable force solenoid valve directly controls the
hydraulic pressure inside the underdrive brake.
Inspection
1.
Turn ignition switch OFF.
2.
Disconnect the solenoid valve connector.
3.
Measure resistance between sensor signal terminal and sensor ground terminal.
4.
Check that the ...
Specifications
Direct control VFS[UD/B]
? Control type : Normal low type
Control Pressure [kpa (kgf/cm?, psi)] 500.14 ~ 9.81(5.1 ~ 0.1, 72.54 ~ 1.42)Current value(mA)50~850 Internal resis ...
See also:
Battery
...
Height Adjust Repair procedures
Replacement
1.
Remove the front seat belt upper anchor.
(Refer to Front Seat Belt - "Front Seat Belt Pretensioner")
2.
After loosening the bolts, then remove the height adjustor (A).
Tigh ...
Vapor hose and fuel filler cap
The vapor hose and fuel filler cap should be inspected at those intervals specified
in the maintenance schedule. Make sure that a new vapor hose or fuel filler cap