Removal |
1. |
Disconnect the vapor hose (A). |
2. |
Remove the PCV valve (B). |
Inspection |
1. |
Insert a thin stick (A) into the PCV valve (B) from the threaded side to check that the plunger moves.
|
Installation |
1. |
Installation is reverse of removal.
|
Oil Filter Components and Components Location
Components
1. Oil filter cap2. O-ring3. Oil filter element4. Oil filter body
...
Trunk Lid Key Holder Components and Components Location
Component Location
1. Trunk lid key holder
...
Heated Oxygen Sensor (HO2S) Specifications
Specification
[Bank 1 / sensor 2, Bank 2 / sensor 2]
A/F Ratio (?)Output Voltage(V)RICHMin. 0.8LEANMax. 0.1
ItemSpecificationHeater Resistance (?)3.3 ~ 4.1[20°C(68°F)]