Hyundai Equus Manuals

Hyundai Azera: Refrigerant line Repair procedures - Air Conditioning System - Heating,Ventilation, Air Conditioning - Hyundai Azera 2011-2026 Service ManualHyundai Azera: Refrigerant line Repair procedures

Replacement
1.
Discharge refrigerant from refrigeration system.
2.
Replace faulty tube or hose.
   
Cap the open fittings immediately to keep moisture or dirt out of the system.
3.
Tighten joint of bolt or nut to specified torque.
   
Connections should not be torque tighter than the specified torque.
4.
Evacuate air in refrigeration system and charge system with refrigerant.

Specified amount : 19.4 ± 0.88 oz.(550 ± 25g)

5.
Inspect for leakage of refrigerant.
Using a gas leak detector, check for leakage of refrigerant.
6.
Inspect A/C operation.
Refrigerant line Components and Components Location
Component Location ...

Compressor Components and Components Location
Components 1. Screw2. Bolt3. Limiter Assembly4. Retainer Ring5. Pulley6. Connector Bracket7. Compressor Assembly ...

See also:

Recommended SAE viscosity number
Always be sure to clean the area around any filler plug, drain plug, or dipstick before checking or draining any lubricant. This is especially important in dusty or sandy areas and when the vehicle ...

Relay Box (Passenger Compartment) Components and Components Location
Components ...

Instrument Cluster Components and Components Location
Components Input/Output Specification ...