Hyundai Equus Manuals

Hyundai Azera: Blower Motor Repair procedures - Blower - Heating,Ventilation, Air Conditioning - Hyundai Azera 2011-2025 Service ManualHyundai Azera: Blower Motor Repair procedures

Inspection
1.
Connect the battery voltage and check the blower motor rotation.

2.
If the blower motor voltage is not operated well, substitute with a known-good blower motor and check for proper operation.
3.
If the problem is corrected, replace the blower motor.
Replacement
1.
Disconnect the negative (-) battery terminal.
2.
Remove the crash pad lower cover (A) and then disconnect the connector (B).

3.
Disconnect the of the blower motor connector(A) and then remove the blower motor (B).

4.
Installation is the reverse order of removal.
Blower Unit Repair procedures
Replacement 1. Disconnect the negative (-) battery terminal. 2. Remove the heater and blower unit. (Refer to Heater - "Heater Unit") 3. Remove the blower unit (A) from the heater unit ...

Power Mosfet Repair procedures
Inspection 1. Ignition "ON" 2. Manually operate the control switch and measure the voltage of blower motor. 3. Select the control switch to raise voltage until high speed. 1. Drain2. Dr ...

See also:

Hood Latch Release Handle Repair procedures
Replacement 1. Using a screwdriver or remover, remove the hood release handle (A).     • Use a 6mm hex bit to press the center until the handle easily pulls off the post. ...

General Safety Information and Caution
Instructions When Handling Refrigerant 1. R-134a liquid refrigerant is highly volatile. A drop on the skin of your hand could result in localized frostbite. When handling the refrigerant, be ...

Tire replacement
If the tire is worn evenly, a tread wear indicator will appear as a solid band across the tread. This shows there is less than 1/16 inch (1.6 mm) of tread left on the tire. Replace the tire when t ...