Hyundai Azera: Purge Control Solenoid Valve (PCSV) Specifications
| Specification |
| Item | Specification |
| Coil Resistance (?) | 22.0 ~ 26.0 [20°C(68°F)] |
Purge Control Solenoid Valve (PCSV) Description and Operation
Purge Control Solenoid Valve (PCSV) Schematic DiagramsComponents and Components Location
Components
1. Rear bumper cover2. Rear bumper lower side bracket3. Rear bumper side bracket
...
On-board Refueling Vapor Recovery (ORVR) valve Repair procedures
Removal
1.
Turn the ignition switch OFF, and then remove battery (-) cable.
2.
Remove the fuel tank.
(Refer to Fuel System - "Fuel Tank")
3.
Disconnect the vapor hose (A).
4.
Remove ...
Manifold Absolute Pressure Sensor (MAPS) Repair procedures
Inspection
1.
Connect the GDS on the Data Link Connector (DLC).
2.
Measure the output voltage of the MAPS at idle and IG ON.
ConditionOutput Voltage (V)IG ONApprox. 4.44VIdleApprox. 0.75V
...