Specifications |
Control Pressure [kpa (kgf/cm?, psi)] | 9.81 ~ 500.14 (0.1 ~ 5.1, 1.42 ~ 72.54) |
Current value(mA) | 50~850 |
Internal resistance(?) | 5.1 |
Reservoir Tank Repair procedures
Removal and Installation
1.
Disconnect the over flow hose (A), and then remove the resorvior tank (B).
Tightening torque:
3.9 ~ 5.9 N.m (0.4 ~ 0.6 kgf.m, 2.9 ~ 4.3 lb-ft)
2.
Installation ...
Input Speed Sensor Repair procedures
Inspection
1.
Check signal waveform of Input & output speed sensor using the GDS.
Specification: Refer to "Signal Wave Form" section.
Removal
1.
Remove the battery and the battery ...
Condenser Repair procedures
Inspection
1.
Check the condenser fins for clogging and damage. If clogged,
clean them with water, and blow them with compressed air. If bent,
gently bend them using a screwdriver or pliers.
...