Hyundai Azera: Torque Converter Control Solenoid Valve (T/CON_VFS) Specifications
| Specifications |
| Control Pressure [kpa (kgf/cm?, psi)] | 9.81~ 500.14 (0.1~ 5.1, 1.42 ~ 72.54) |
| Current value(mA) | 50 ~ 850 |
| Internal resistance(?) | 5.1 |
Torque Converter Control Solenoid Valve (T/CON_VFS) Description and Operation
Torque Converter Control Solenoid Valve (T/CON_VFS) Schematic DiagramsStarter Relay Repair procedures
Inspection
1.
Remove the fuse box cover.
2.
Remove the starter relay (A).
3.
Using an ohmmeter, check that there is continuity between each terminal.
TerminalContinuity30 - 87NO85 - 86Y ...
CVVT Assembly Description and Operation
Description
Continuous Variable Valve Timing (CVVT) system advances or
retards the valve timing of the intake and exhaust valve in accordance
with the ECM control signal which is calculated by ...
Ambient Sensor Description and Operation
Description
1.
The ambient temperature sensor is located at the front of the
condenser and detects ambient air temperature. It is a negative type
thermistor resistance will increase with lower ...