Hyundai Azera: Blower Motor Repair procedures - Blower - Heating,Ventilation, Air Conditioning - Hyundai Azera 2011-2025 Service ManualHyundai Azera: Blower Motor Repair procedures

Inspection
1.
Connect the battery voltage and check the blower motor rotation.

2.
If the blower motor voltage is not operated well, substitute with a known-good blower motor and check for proper operation.
3.
If the problem is corrected, replace the blower motor.
Replacement
1.
Disconnect the negative (-) battery terminal.
2.
Remove the crash pad lower cover (A) and then disconnect the connector (B).

3.
Disconnect the of the blower motor connector(A) and then remove the blower motor (B).

4.
Installation is the reverse order of removal.
Blower Unit Repair procedures
Replacement 1. Disconnect the negative (-) battery terminal. 2. Remove the heater and blower unit. (Refer to Heater - "Heater Unit") 3. Remove the blower unit (A) from the heater unit ...

Power Mosfet Repair procedures
Inspection 1. Ignition "ON" 2. Manually operate the control switch and measure the voltage of blower motor. 3. Select the control switch to raise voltage until high speed. 1. Drain2. Dr ...

See also:

General Safety Information and Caution
Smart Cruise Control Be careful when driving the vehicle using the smart cruise control system as follows.     • The smart cruise control system may have limits to detect di ...

Starter Repair procedures
Removal and Installation 1. Disconnect the battery negative terminal. 2. Remove the engine room under cover. 3. Remove the starter cover (A). Tightening torque : Bolts: 8.8 ~ 13.7 N. ...

Underdrive Brake Control Solenoid Valve(UD/B_VFS) Specifications