Heated Oxygen Sensor (HO2S) consists of the zirconium and the
alumina and is installed on upstream and downstream of the Warm-up
Catalytic Converter (WCC).
After it compares oxygen consistency of the atmosphere with
the exhaust gas, it transfers the oxygen consistency of the exhaust gas
to the ECM. When A/F ratio is rich or lean, it generates approximately
1V or 0V respectively. In order that this sensor normally operates, the
temperature of the sensor tip is higher than 370°C (698°F). So it has a
heater which is controlled by the ECM duty signal.
When the exhaust gas temperature is lower than the specified value, the heater warms the sensor tip.

Removal
[Knock Sensor #1 (Bank 1)]
1.
Turn the ignition switch OFF and disconnect the battery negative (-) cable.
2.
Disconnect the knock sensor connector (A).
3.
Remove the intake man ...
Specification
[Bank 1 / sensor 2, Bank 2 / sensor 2]
A/F Ratio (?)Output Voltage(V)RICHMin. 0.8LEANMax. 0.1
ItemSpecificationHeater Resistance (?)3.3 ~ 4.1[20°C(68°F)]
[Bank 1 / sensor 1, ...
See also:
Water pump Troubleshooting
Troubleshooting
SymptomsPossible CausesRemedyCoolant leakage
•
From the bleed hole of the water pump
Visually check
•
Check leaks after about ten-minute warming up.
•
If coolant st ...
Description and Operation
Description
•
EPS (Electric power steering, Column assist type) system uses
an electric motor to assist the steering force and it is an engine
operation independent steering system.
• ...
Panoramaroof Assembly Repair procedures
Removal
1.
Remove the roof trim.
(Refer to Roof Trim - "Roof Trim Assembly")
2.
Remove the rear window glass.
(Refer to "Rear Window Glass")
3.
Remove the movable glass.
(Refer to Panor ...